Remote Radio Control over IP -- MADE IN GERMANY
RRC101-IP
The RRC101-IP uses the RoIP-Technology (Radio over Internet Protocol). RoIP is an extension of the known Voice over IP (VoIP), in which additional datas for link connection, PTT, Squelch and Channel are transferred and offer the opportunity for the remote controlling of radio transceiver.
To transmit voice, data and signals, the specific developed Radio over Internet Protocol (RoIP) will be carried out.
It is easy to integrate the RRC101-IP in existing networks or the Internet. Using existing IP infrastructure (WAN, LAN, Internet, VPN) offers a cost efficient way to connect radio systems and operators.
Via the transparent Serial- and Parallel-Interface, additional data can be transferred and enables remote channel switch-over of radio transceiver or alerting. To switch-over the radio channels is also possible through the serial (RS232) or parallel interface.
The RRC101-IP is available in two versions:
Black Box (RRC101-IP-B) with mounting flange |
19-Inch-Slide-In-Module (RRC101-IP-19) height = 3 U, width = 10 HP |
For the power supply we recommend our optional switching power supply SNT18.
The configuration of the RRC101-IP can be done over the webinterface or USB Flash-Drive.
After copying the data on the USB Flash-Drive, the Flash-Drive is connected with the USB-Port of the RRC101-IP. The configuration data are automatically downloaded. After the compleated transfer the Flash-Drive can be removed.
Updates are done the same way.
Monitoring, updating and configuration is possible with SSH or serial interface.
Is the RRC101-IP over a gateway connected with the Internet, it can be operated and maintained worldwide.
Specifications
General |
|
Supply Voltage | +9 to +16 VDC, nominal 12 V, max. 300 mA |
Operating Temperature Range | -20 to + 60° C |
Humidity | Up to 95% by 55° C |
Display Front Panel | 5 LED's – Power, Link-Active, 10/100 Mbit, Tx active, Rx aktive |
Weight | ca. 560 gr |
Programming / Configuration | USB-Flash-Drive, RS-232, Secure Shell, Webinterface |
Rx Audio Input |
|
Input Resistance | 10 kΩ |
Input Voltage | 500 mV (70 – 800 mV adjustable) |
Frequency Range | 60 Hz - 3400 kHz (- 2 dB) |
Signal to Noise Ratio | better 60 dB |
TX Audio Output |
|
Output Resistance | min. 20 Ω, nominal 35 Ω |
Output Voltage | 500 mV nominal (2,0 – 1000 mV adjustable) |
Frequency Range | 60 Hz - 3400 kHz (- 2 dB) |
Signal to Noise Ratio | better 60 dB |
Digital Ausgang (PTT) |
|
Output | Solid-State Relays |
Max. Sink Current | 250 mA (AC or DC) |
Max. Open Circuit Voltage | +/- 250 V |
Digital Input (SQUELCH) |
|
Input | Opto coupler |
Input Resistance | 1 kΩ |
Polarity | Active low or high, adjustable |
Limit | +1,5 V nominal |
Protection Up To | +/- 30 V |
2 Serial Interfaces |
|
Interface-Type | RS-232, asynchron, Full Duplex |
Baudrate | 4800, 9600, 19200, 38400, 57600, 115200 bps |
Connector | RJ45 extern, one intern |
Network |
|
Interface-Type | 10/100 Mbps Ethernet, RJ-45 |
Protocols | UDP, TCP/IP, ftp, http, bootp, tftp, ssh (more Protocols e.g. Telnet on Demand) |
Audio encoder / decoder | Speex codec |
Additional digital In- / Output |
|
Inputtype | Tristate, 0 or 3,3 V |
Outputtype | Tristate, 0 or 3,3 V, 50 mA |
Number of In / Outputs | 7 (5 by use of the extern RS232-Interface) |
More Informations
For more informations, like Service-Manual or Flyer, see Service & Support.